Insertion Flow Probe Meter Specification Chart

Probe SpecificationModel # 62-9
Pipe / Line Size:2½” SCH 40 to Unlimited
Flow Measuring Capability:
Gas:40 to 15,000 SFPM
Liquid:.01 to 15 Feet per Second
Temperature Range:
Fahrenheit:-20 to 350
Celsius:-28 to 162

 

ENGINEERING SPECIFICATIONSMounting:
Integral to the Flow Transducer
Accuracy: +/- .50% of Full Scale, [or 2.0% of reading whichever is better. Full Scale over the calibrated range. [Process fluid temperature span +/- 50°F]Remote to 4000 ft., Wall or Frame mount
Repeatability: +/- 0.2 % of RateSignal Cable for Remote Design: 18 gauge, 2 pair with cable shield. Maximum distance, 4000 ft.
Response Time:MODEL NUMBERING SYSTEM:
Gases: 1 to 2 sec. TypicalBase Model: = 9500
Liquids: Less than 500ms
Pressure Rating:Electronics Mounting:
0 – 1200 psig (Std)I = Integral Mount
0 – 10000 psig Dependent on meter sizeR = Remote Mount
F = Fluid
Flow Rates:G = Gas
Gas: 40 to 86,000 SFPML = Liquid
Liquid: .02 to 20 FPS
Note: maximum determined by pipe capacity
Flow Range: 100:1 Std. Multiple ranges availableMaterial:
316SS = STD
Calibrated Temperature Range:Corrosion Resistant Materials available by request: Hastelloy C, Monel, Inconel, Tantalum, and Carpenter 20
Gas: -20 F to 350 F (-28°C to 162°C )STD.Available Coatings: Carbide, Fluorocarbon , Teflon, and Sulfinert
[-20°F to 600°F] (-28°C to 315°C) Optional)Process Connection:
Liquid: -20F to 350F (-28°C to 162°C ) STD.PG = Packing Gland (Std.)
[ -20°F to 500°F](-28°C to 260°C) OptionalFLG-150 =150# RF Flange (Std.Van stone)
TC = Triclover
Wetted Materials: 316SS (STD). Consult the factory for other material requirementsFLG-Other = Consult Factory
Other = Consult Factory
Connections: Flange, Packing Gland, Triclover, Hot Tap
Power:
Calibration Temperature Capability: -20°F to 600°F(-29°C to 315°C)24 = 22-26 VDC, 1 AMP. 4 WIRE
120 = 120VAC, 1/2 AMP, 50/60 HZ (STD.)
MICRO-CONTROLLER SPECIFICATIONS:240 = 240VAC 50/60 HZ
16 BIT A/D
Output Signals:
Displays: Bright LED 2 Line 8 digit(Select One**)
Capable of displaying Current Flowrate and Total Flow (Optional)0/5 = 0-5 VDC**
0/10 = 0-10 VDC**
Communicator:4/20 = 4-20 mADC** into 750 ohms, Isolated std, Self Powered
Interface: RS-232 via Ribbon Connector4/20T = Opt Process Fluid Temp. 4-20mA Self Powered
Baud Rate: 9600Other = Consult Factory
Filter Factor
Flow Full ScaleDisplay: (Optional)
Flow Rate Decimal PointND = No Display
Flow Totalizer Decimal PointD = Flowrate Display, 8 Digit
Flow Totalizer Flowrate Ratio8T = Totalizer
D/8T = Flowrate and Total Display, 8 digit
Power:
120/240 vat, 50/60 Hz.Signal Cable for Remote Design: SC25 = 25 FT Supplied with remote configuration
24VDC, 1 Amp (Factory Set)
Electrical Connections:3/4” FNPT Power & Signal
Enclosure: Cast Aluminum, Epoxy Painted
Environmental Ratings:
Housing: Explosion Proof, Class 1, Div. 1, Groups, B, C D
Weatherproof: Nema 4
Ambient Temperature: -25 to 60 C (-13 to 140 F)
Storage Temperature: -40 to 70 C ( -40 to 158F )