Technical Paper: Accurate Landfill Gas Measurement via Thermal Mass Flow Metering

Subject: Optimizing Landfill Gas (LFG) Flow Monitoring with Thermal Instrument Company Equipment: Model 62-9TEF Insertion Probe / Integral 9500P Electronics

Author: Thermal Instrument Company Engineering Team

Abstract

Landfill Gas (LFG) extraction and flare/energy monitoring present harsh operational environments characterized by variable gas compositions, moisture, particulate build-up, and wide dynamic flow ranges. Regulatory compliance mandates accurate, repeatable flow rate monitoring for both environmental reporting and bio-energy production efficiency. This paper details the operational advantages of applying the Thermal Instrument Company (TIC) Model 62-9TEF Insertion Probe paired with Integral 9500P Electronics, highlighting sensor architecture, operational durability, and TIC’s comprehensive lifecycle support programs (recalibration, loaner meter support, and field service).

1. Landfill Gas Generation & Regulatory Context

Landfill Gas is produced as solid organic waste undergoes anaerobic decomposition within sealed landfill cells. Isolated from oxygen, groundwater, and ambient air by composite liners and soil covers, methanogenic bacteria break down organic matter into a combustible gas stream consisting primarily of:

Methane (CH4): 50% – 60% by volume

Carbon Dioxide (CO2): 35% – 45% by volume

Trace Components: Nitrogen (N2), Oxygen (O2), moisture (H2O vapor), hydrogen sulfide (H2S), and non-methane organic compounds (NMOCs).

Federal environmental regulations dictate that landfill operators capture LFG via a network of extraction wells, header pipes, and blower skids. Captured gas must be utilized for renewable energy generation (e.g., direct-use boilers, gas-to-grid processing, or power generation) or destroyed via thermal flaring. Environmental authorities mandate continuous, accurate mass flow rate measurement and data logging for emissions accounting and compliance verification.

Process:

2. Technical Challenges of LFG Flow Measurement

Measuring LFG accurately presents severe technical challenges for traditional flow measurement technologies:

Compositional Variations: Fluctuations in the CH4/CO2 ratio affect thermodynamic gas properties.

Dynamic Range Requirements: Seasonal changes, well field balancing, and blower output lead to wide velocity swings between peak production and low-flow flare conditions.

Contaminants & Condensate: Entrained particulate matter, siloxanes, and moisture build up on exposed flow elements, drift sensor calibration, and increase maintenance cycles.

Pressure Drops: Unnecessary pressure drops burden blower skids and decrease system extraction efficiency.

3. Technology Principles: Model 62-9TEF Thermal Mass Flow Sensor

Thermal Mass Flow Measurement operates on the principle of thermal dispersion, measuring mass flow directly without requiring separate pressure or temperature compensation inputs.

Key Engineering Features of the Model 62-9TEF:

Direct Mass Flow Measurement: Automatically compensates for process temperature and pressure variations.

100:1 Dynamic Turndown Ratio: Accurately registers low ambient flare flows as well as high-velocity production runs.

Non-Obstructive / Low Pressure Drop: Insertion probe geometry minimizes head loss across the header line, optimizing blower power consumption.

Solid-State Construction (No Moving Parts): Eliminates mechanical wear, bearing failures, and jammed impellers.

Protected Sensor Architecture: Unlike standard thermal sensors where RTDs are directly exposed to process fluids, TIC sensors are housed inside our 316SS insertion probe, ensuring the sensing elements never come into direct contact with the LFG stream.

Teflon Coating: Protects the sensor tip area from sticky particulate, moisture, and siloxane build-up, preserving flow profile consistency and reducing cleaning frequency.

Redundant Back-Up Sensors: Built-in redundancy inside every probe tip extends operating life and ensures continuous uptime in remote, harsh monitoring environments.

4. Advanced Signal Processing: Integral 9500P Electronics

When paired with the Model 62-9TEF Insertion Probe, the Integral 9500P Electronics transmitter converts raw thermal dispersion signals into precision flow measurements.

Key Features & Benefits:

Factory-Calibrated Gas Curve (Exact CH4 / CO2 Mix). Ready to go right out of the box

Temperature & Pressure Compensation

Linearized Output Signal: Standard 4-20mA Current Loop

Integrated Diagnostic Routines & Local Display Capability

System Configuration Comparison

Operational Feature Standard Flow Meters Thermal Instrument 62-9TEF/9500P

Pressure / Temperature Compensation Requires external sensors & computers Inherent (Direct Mass Flow)

Turndown Ratio 10:1 to 15:1 Average 100:1 Wide Dynamic Range

Sensor Protection Exposed Sensing Elements Fully Protected. No Direct Contact

Sensor Redundancy Single point of failure Built-in Redundant Back-up Sensors

Pressure Drop Moderate to high (Orifice Plate / Turbines Negligible

Maintenance Impact High (frequent cleaning) Low (No Moving Parts, Single Piece Construction, Teflon Coated)

5. Lifecycle, Recalibration & Compliance Support

Accurate flow monitoring over years of continuous operation requires reliable field support and calibration maintenance. Thermal Instrument Company provides tailored service structures to ensure zero downtime and ongoing regulatory compliance:

Factory Gas-Specific Recalibration: Recalibration services tailored to your exact site gas composition and line dimensions, easily managed via TIC's streamlined web-based order system.

On-Site Field Service & Calibration Options: Factory-trained technicians conduct on-site verification, functional testing, and field calibration to ensure zero interruption to reporting schedules.

Loaner Meter Program: To ensure continuous compliance and uncompromised flow logging during routine factory maintenance or recalibration, TIC provides temporary loaner meters.

4-Year Factory Warranty: Backed by decades of dedicated service to the landfill and biogas industries, TIC delivers long-term operational confidence.

6. Conclusion

Accurate landfill gas monitoring requires equipment capable of handling fluctuating gas ratios, harsh environments, and wide flow ranges without maintenance-heavy downtime. The Thermal Instrument Model 62-9TEF Mass Flow Insertion Probe combined with Integral 9500P Electronics offers a robust, low-maintenance, and highly accurate solution tailored to regulatory and bio-energy monitoring demands.

For more information please contact us.